Overcurrent E2

The red LED flashes every 5 seconds. Pressure too high (>70 bar). The FlexxPump stops operating.

Overcurrent E2

Malfunction

Cause

Measure

Overcurrent E2

Line or lubrication point is blocked:

  • Lubricant too hard
  • Lubrication point blocked
  • Hoses too long

Remove blockage

Remove the blockage as follows:

  1. Switch off FlexxPump
  1. Analyze blockage
  1. Remove blockage
  1. Switch on the FlexxPumpSwitching on the FlexxPump 402/402B
  1. Evaluate success
  1. If there are deviations: Repeat process from step 1
  • The blockage is removed.