Internal mechanical error E5
The red LED flashes every 5 seconds. The FlexxPump stops operating.
Malfunction | Cause | Measure |
---|---|---|
Internal mechanical error E5 | Mechanical error | Carry out a special dispensingSpecial dispensing If unsuccessful: Send FlexxPump to Güdel for inspection or repair. |
Fix the mechanical fault as follows:
- Switch off FlexxPumpSwitching off FlexxPump 402/402B
- Switch on the FlexxPumpSwitching on the FlexxPump 402/402B
- Carry out a special dispensingSpecial dispensing
- If fault message E5 reoccurs immediately: Send FlexxPump to Güdel for inspection or repair.
- If FlexxPump works without another fault message E5: No other action required.
- The mechanical fault has been corrected.