Replacing the cartridge
Replace the cartridge if the malfunction message "Empty" appears.
Switch on or off pump type 404DLS via PLC.
CAUTION
Residual amounts in empty cartridges
Empty cartridges contain lubricant residues. Oils and greases are harmful to the environment!
- Dispose of the cartridge in an environmentally friendly mannerDisposal
CAUTION
Danger from spring tension
The covering contains a spring with tension. The covering jumps up when opened. This can lead to minor injuries!
Make sure that no extremities are in the danger area. Carefully remove the covering.
HINT
Use only original Güdel cartridges. Never refill the cartridges.
A | Vent locking mechanism | D | O-ring |
B | Cartridge | E | Retaining covering |
C | Covering |
Lubrication ex works | Specification | Lubrication quantity |
---|---|---|
400 cm³ |
Replace the cartridge as follows:
- Remove the vent locking mechanism in the direction of the arrow
- Switch off FlexxPump
- Remove the covering by turning in the direction of the arrow
- Remove empty cartridge
- Remove the retaining covering from the new cartridge
- Lubricate the O-ring slightly
- Insert new cartridge (make sure the cartridge fits in properly)
- Put on the covering and turn hand-tight in the direction of the arrow
- Switch on the FlexxPump
- Insert vent locking mechanism and secure
- Check the lubrication systemChecking the lubrication system
- The cartridge is replaced.